Browsing by Author "Contreras, Roberto"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
- ItemCapillary refill time response to a fluid challenge or a vasopressor test: an observational, proof-of-concept study(2024) Hernández, Glenn; Valenzuela, Emilio Daniel; Kattan, Eduardo; Castro, Ricardo; Guzmán, Camila; Kraemer, Alicia Elzo; Sarzosa, Nicolás; Alegria, Leyla; Contreras, Roberto; Oviedo, Vanessa; Bravo, Sebastián; Soto, Dagoberto; Sáez, Claudia; Ait-Oufella, Hafid; Ospina Tascón, Gustavo; Bakker, JanBackground: Several studies have validated capillary refill time (CRT) as a marker of tissue hypoperfusion, and recent guidelines recommend CRT monitoring during septic shock resuscitation. Therefore, it is relevant to further explore its kinetics of response to short-term hemodynamic interventions with fluids or vasopressors. A couple of previous studies explored the impact of a fluid bolus on CRT, but little is known about the impact of norepinephrine on CRT when aiming at a higher mean arterial pressure (MAP) target in septic shock. We designed this observational study to further evaluate the effect of a fluid challenge (FC) and a vasopressor test (VPT) on CRT in septic shock patients with abnormal CRT after initial resuscitation. Our purpose was to determine the effects of a FC in fluid-responsive patients, and of a VPT aimed at a higher MAP target in chronically hypertensive fluid-unresponsive patients on the direction and magnitude of CRT response. Methods Thirty-four septic shock patients were included. Fluid responsiveness was assessed at baseline, and a FC (500 ml/30 mins) was administered in 9 fluid-responsive patients. A VPT was performed in 25 patients by increasing norepinephrine dose to reach a MAP to 80–85 mmHg for 30 min. Patients shared a multimodal perfusion and hemodynamic monitoring protocol with assessments at at least two time-points (baseline, and at the end of interventions). Results CRT decreased significantly with both tests (from 5 [3.5–7.6] to 4 [2.4–5.1] sec, p = 0.008 after the FC; and from 4.0 [3.3–5.6] to 3 [2.6 -5] sec, p = 0.03 after the VPT. A CRT-response was observed in 7/9 patients after the FC, and in 14/25 pts after the VPT, but CRT deteriorated in 4 patients on this latter group, all of them receiving a concomitant low-dose vasopressin. Conclusions Our findings support that fluid boluses may improve CRT or produce neutral effects in fluid-responsive septic shock patients with persistent hypoperfusion. Conversely, raising NE doses to target a higher MAP in previously hypertensive patients elicits a more heterogeneous response, improving CRT in the majority, but deteriorating skin perfusion in some patients, a fact that deserves further research.
- ItemDynamic changes of hepatic vein Doppler velocities predict preload responsiveness in mechanically ventilated critically ill patients(2024) Bruna, Mario; Alfaro, Sebastián; Muñoz Ferrada, Felipe Ignacio; Cisternas, Liliana; González, Cecilia; Conlledo, Rodrigo; Ulloa Morrison, Rodrigo; Huilcaman, Marcos; Retamal, Jaime; Castro López, Ricardo; Rola, Philippe; Wong, Adrian; Argaiz, Eduardo R.; Contreras, Roberto; Hernández P., Glenn; Kattan Tala, Eduardo JoséBackground: Assessment of dynamic parameters to guide fluid administration is one of the mainstays of current resuscitation strategies. Each test has its own limitations, but passive leg raising (PLR) has emerged as one of the most versatile preload responsiveness tests. However, it requires real-time cardiac output (CO) measurement either through advanced monitoring devices, which are not routinely available, or echocardiography, which is not always feasible. Analysis of the hepatic vein Doppler waveform change, a simpler ultrasound-based assessment, during a dynamic test such as PLR could be useful in predicting preload responsiveness. The objective of this study was to assess the diagnostic accuracy of hepatic vein Doppler S and D-wave velocities during PLR as a predictor of preload responsiveness. Methods: Prospective observational study conducted in two medical–surgical ICUs in Chile. Patients in circulatory failure and connected to controlled mechanical ventilation were included from August to December 2023. A baseline ultrasound assessment of cardiac function was performed. Then, simultaneously, ultrasound measurements of hepatic vein Doppler S and D waves and cardiac output by continuous pulse contour analysis device were performed during a PLR maneuver. Results: Thirty-seven patients were analyzed. 63% of the patients were preload responsive defined by a 10% increase in CO after passive leg raising. A 20% increase in the maximum S wave velocity after PLR showed the best diagnostic accuracy with a sensitivity of 69.6% (49.1–84.4) and specificity of 92.8 (68.5–99.6) to detect preload responsiveness, with an area under curve of receiving operator characteristic (AUC–ROC) of 0.82 ± 0.07 (p = 0.001 vs. AUC–ROC of 0.5). D-wave velocities showed worse diagnostic accuracy. Conclusions: Hepatic vein Doppler assessment emerges as a novel complementary technique with adequate predictive capacity to identify preload responsiveness in patients in mechanical ventilation and circulatory failure. This technique could become valuable in scenarios of basic hemodynamic monitoring and when echocardiography is not feasible. Future studies should confirm these results.
- ItemExploring the relationship between capillary refill time, skin blood flow and microcirculatory reactivity during early resuscitation of patients with septic shock: a pilot study(2023) Contreras, Roberto; Hernandez, Glenn; Daniel Valenzuela, Emilio; Gonzalez, Cecilia; Ulloa, Rodrigo; Soto, Dagoberto; Castro, Ricardo; Guzman, Camila; Oviedo, Vanessa; Alegria, Leyla; Vidal, Diego; Morales, Sebastian; Adolfo Ospina-Tascon, Gustavo; Bakker, Jan; Kattan, EduardoCapillary refill time (CRT), a costless and widely available tool, has emerged as a promising target to guide septic shock resuscitation. However, it has yet to gain universal acceptance due to its potential inter-observer variability. Standardization of CRT assessment may minimize this problem, but few studies have compared this approach with techniques that directly assess skin blood flow (SBF). Our objective was to determine if an abnormal CRT is associated with impaired SBF and microvascular reactivity in early septic shock patients. Twelve septic shock patients were subjected to multimodal perfusion and hemodynamic monitoring for 24 h. Three time-points (0, 1, and 24 h) were registered for each patient. SBF was measured by laser doppler. We performed a baseline SBF measurement and two microvascular reactivity tests: one with a thermal challenge at 44 & DEG;C and other with a vascular occlusion test. Ten healthy volunteers were evaluated to obtain reference values. The patients (median age 70 years) exhibited a 28-day mortality of 50%. Baseline CRT was 3.3 [2.7-7.3] seconds. In pooled data analysis, abnormal CRT presented a significantly lower SBF when compared to normal CRT [44 (13.3-80.3) vs 193.2 (99.4-285) APU, p = 0.0001]. CRT was strongly associated with SBF (R-2 0.76, p < 0.0001). An abnormal CRT also was associated with impaired thermal challenge and vascular occlusion tests. Abnormal CRT values observed during early septic shock resuscitation are associated with impaired skin blood flow, and abnormal skin microvascular reactivity. Future studies should confirm these results.