Browsing by Author "Nordio, Giovanna"
Now showing 1 - 5 of 5
Results Per Page
Sort Options
- Item3D myocardial T-1 mapping using saturation recovery(2017) Nordio, Giovanna; Henningsson, Markus; Chiribiri, Amedeo; Villa, Adriana D. M.; Schneider, Torben; Botnar, René Michael
- Item3D SASHA myocardial T1 mapping with high accuracy and improved precision(2019) Nordio, Giovanna; Bustin, Aurélien; Henningsson, Markus; Rashid, Imran; Chiribiri, Amedeo; Ismail, Tevfik; Odille, Freddy; Prieto Vásquez, Claudia; Botnar, René Michael
- ItemAccelerated high-resolution free-breathing 3D whole-heart T2-prepared black-blood and bright-blood cardiovascular magnetic resonance(2020) Correia, Teresa; Botnar, René Michael; Prieto Vásquez, Claudia; Ginami, Giulia; Rashid, Imran; Nordio, Giovanna; Hajhosseiny, R.; Ismail, Tevfik F.; Neji, RadhoueneAbstract Background The free-breathing 3D whole-heart T2-prepared Bright-blood and black-blOOd phase SensiTive inversion recovery (BOOST) cardiovascular magnetic resonance (CMR) sequence was recently proposed for simultaneous bright-blood coronary CMR angiography and black-blood late gadolinium enhancement (LGE) imaging. This sequence enables simultaneous visualization of cardiac anatomy, coronary arteries and fibrosis. However, high-resolution (< 1.4 × 1.4 × 1.4 mm3) fully-sampled BOOST requires long acquisition times of ~ 20 min. Methods In this work, we propose to extend a highly efficient respiratory-resolved motion-corrected reconstruction framework (XD-ORCCA) to T2-prepared BOOST to enable high-resolution 3D whole-heart coronary CMR angiography and black-blood LGE in a clinically feasible scan time. Twelve healthy subjects were imaged without contrast injection (pre-contrast BOOST) and 10 patients with suspected cardiovascular disease were imaged after contrast injection (post-contrast BOOST). A quantitative analysis software was used to compare accelerated pre-contrast BOOST against the fully-sampled counterpart (vessel sharpness and length of the left and right coronary arteries). Moreover, three cardiologists performed diagnostic image quality scoring for clinical 2D LGE and both bright- and black-blood 3D BOOST imaging using a 4-point scale (1–4, non-diagnostic–fully diagnostic). A two one-sided test of equivalence (TOST) was performed to compare the pre-contrast BOOST images. Nonparametric TOST was performed to compare post-contrast BOOST image quality scores. Results The proposed method produces images from 3.8 × accelerated non-contrast-enhanced BOOST acquisitions with comparable vessel length and sharpness to those obtained from fully- sampled scans in healthy subjects. Moreover, in terms of visual grading, the 3D BOOST LGE datasets (median 4) and the clinical 2D counterpart (median 3.5) were found to be statistically equivalent (p < 0.05). In addition, bright-blood BOOST images allowed for visualization of the proximal and middle left anterior descending and right coronary sections with high diagnostic quality (mean score > 3.5). Conclusions The proposed framework provides high‐resolution 3D whole-heart BOOST images from a single free-breathing acquisition in ~ 7 min.
- ItemAccelerating 3D MTC-BOOST in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction(2022) Fotaki, Anastasia; Fuin, Niccolo; Nordio, Giovanna; Jimeno, Carlos Velasco; Qi, Haikun; Emmanuel, Yaso; Pushparajah, Kuberan; Botnar, Rene M.; Prieto, ClaudiaPurpose: Free-breathing Magnetization Transfer Contrast Bright blOOd phase SensiTive (MTC-BOOST) is a pro-totype balanced-Steady-State Free Precession sequence for 3D whole-heart imaging, that employs the endoge-nous magnetisation transfer contrast mechanism. This achieves reduction of flow and off-resonance artefacts, that often arise with the clinical T2prepared balanced-Steady-State Free Precession sequence, enabling high quality, contrast-agent free imaging of the thoracic cardiovascular anatomy. Fully-sampled MTC-BOOST acquisition requires long scan times (~10-24 min) and therefore acceleration is needed to permit its clinical incorporation. The aim of this study is to enable and clinically validate the 5-fold accelerated MTC-BOOST acquisition with joint Multi-Scale Variational Neural Network (jMS-VNN) reconstruction. Methods: Thirty-six patients underwent free-breathing, 3D whole-heart imaging with the MTC-BOOST sequence, which is combined with variable density spiral-like Cartesian sampling and 2D image navigators for translational motion estimation. This sequence acquires two differently weighted bright-blood volumes in an interleaved fashion, which are then joined in a phase sensitive inversion recovery reconstruction to obtain a complementary fully co-registered black-blood volume. Data from eighteen patients were used for training, whereas data from the remaining eighteen patients were used for testing/evaluation. The proposed deep-learning based approach adopts a supervised multi-scale variational neural network for joint reconstruction of the two differently weighted bright-blood volumes acquired with the 5-fold accelerated MTC-BOOST. The two contrast images are stacked as different channels in the network to exploit the shared information. The proposed approach is compared to the fully-sampled MTC-BOOST and 5-fold undersampled MTC-BOOST acquisition with Compressed Sensing (CS) reconstruction in terms of scan/reconstruction time and bright-blood image quality. Comparison against conventional 2-fold undersampled T2-prepared 3D bright-blood whole-heart clinical sequence (T2prep-3DWH) is also included. Results: Acquisition time was 3.0 & PLUSMN; 1.0 min for the 5-fold accelerated MTC-BOOST versus 9.0 +/- 1.1 min for the fully-sampled MTC-BOOST and 11.1 +/- 2.6 min for the T2prep-3DWH (p < 0.001 and p < 0.001, respectively). Reconstruction time was significantly lower with the jMS-VNN method compared to CS (10 +/- 0.5 min vs 20 +/- 2 s, p < 0.001). Image quality was higher for the proposed 5-fold undersampled jMS-VNN versus conventional CS, comparable or higher to the corresponding T2prep-3DWH dataset and similar to the fully-sampled MTC-BOOST. Conclusion: The proposed 5-fold accelerated jMS-VNN MTC-BOOST framework provides efficient 3D whole-heart bright-blood imaging in fast acquisition and reconstruction time with concomitant reduction of flow and off-resonance artefacts, that are frequently encountered with the clinical sequence. Image quality of the cardiac anatomy and thoracic vasculature is comparable or superior to the clinical scan and 5-fold CS reconstruction in faster reconstruction time, promising potential clinical adoption.
- ItemCorrection to: 3D SASHA myocardial T1 mapping with high accuracy and improved precision(2018) Nordio, Giovanna ; Bustin, Aurelien; Henningsson, Markus; Rashid, Imran ; Chiribiri, Amedeo ; Ismail, Tevfik ; Odille, Freddy; Prieto, Claudia; Botnar, Rene Michael