Arterial spin labeling angiography using a triple inversion recovery prepulse

dc.contributor.authorAndia, Marcelo E.
dc.contributor.authorBotnar, Rene M.
dc.date.accessioned2024-01-10T12:04:19Z
dc.date.available2024-01-10T12:04:19Z
dc.date.issued2012
dc.description.abstractArterial spin labeling is a well-known noninvasive angiography technique, which does not necessitate the use of a contrast agent. arterial spin labeling is still clinically underused because of several challenges: (1) long scan times because of the need for two acquisitions (labeled and nonlabeled datasets), (2) sensitivity to spatial misregistration because of the need for image subtraction, and (3) the need for precise planning and choice of an optimal inversion delay for best blood-to-background contrast. In this work, we propose a new arterial spin labeling method based on a triple-inversion-recovery sequence-arterial spin labeling. This approach exploits the ability of two nonselective inversion recovery prepulses to null the background signal over a wide range of T1 values, while maintaining the signal of labeled blood using a third slab selective inversion pulse. This technique therefore allows the acquisition of angiograms with a flexible inversion delay, easier planning procedure and no need for subtraction. Magn Reson Med, 2012. (C) 2011 Wiley Periodicals, Inc.
dc.description.funderChilean Agency for Research in Science and Technology (CONICYT)
dc.description.funderNIHR Biomedical Research Centre (King's College)
dc.format.extent7 páginas
dc.fuente.origenWOS
dc.identifier.doi10.1002/mrm.23028
dc.identifier.issn0740-3194
dc.identifier.pubmedidMEDLINE:21656564
dc.identifier.urihttps://doi.org/10.1002/mrm.23028
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/75758
dc.identifier.wosidWOS:000299376500022
dc.information.autorucMedicina;Andia M;S/I;90691
dc.issue.numero2
dc.language.isoen
dc.nota.accesoSin adjunto
dc.pagina.final483
dc.pagina.inicio477
dc.publisherWILEY-BLACKWELL
dc.revistaMAGNETIC RESONANCE IN MEDICINE
dc.rightsregistro bibliográfico
dc.subjectangiography
dc.subjectnon-contrast-enhanced magnetic resonance angiography
dc.subjectarterial spin labeling
dc.subjecttriple inversion recovery
dc.subjectCHRONIC RENAL-INSUFFICIENCY
dc.subjectCONTRAST-MEDIA
dc.subjectCOMPUTED-TOMOGRAPHY
dc.subjectMR-ANGIOGRAPHY
dc.subjectATHEROSCLEROSIS
dc.subjectRISK
dc.subjectINFLAMMATION
dc.subjectGUIDELINES
dc.subjectLACTATION
dc.subjectPREGNANCY
dc.subject.ods03 Good Health and Well-being
dc.subject.odspa03 Salud y bienestar
dc.titleArterial spin labeling angiography using a triple inversion recovery prepulse
dc.typeartículo
dc.volumen67
sipa.codpersvinculados90691
sipa.indexWOS
sipa.indexScopus
sipa.trazabilidadCarga SIPA;09-01-2024
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Arterial spin labeling angiography using a triple inversion recovery prepulse.pdf
Size:
2.67 KB
Format:
Adobe Portable Document Format
Description: