Feasibility study of the application of a cooling energy storage system in a chiller plant of an office building located in Santiago, Chile

dc.contributor.authorVenegas-Troncoso, Tomas
dc.contributor.authorUgarte-Larraguibel, Gaspar
dc.contributor.authorVasco, Diego A.
dc.contributor.authorRouault, Fabien
dc.contributor.authorPerez, Rodrigo
dc.date.accessioned2025-01-23T21:12:25Z
dc.date.available2025-01-23T21:12:25Z
dc.date.issued2019
dc.description.abstractEnergy consumption of commercial buildings has increasingly gained attention worldwide, because of its significant electricity consumption and peak power demand. Chiller plants are mostly used in commercial buildings to generate cold water for air conditioning. However, because the chiller plants and the refrigeration systems tend to be oversized with respect to their critical design load conditions, they certainly lead to higher energy consumption than a properly sized chiller plant. One possible way to reduce the power consumption and redistribute energy use is through the integration of latent heat thermal energy storage (LHTES) systems with air-cooling system in buildings. In the present work, a LHTES system based on ice is implemented along with a conventional chiller system of an existing commercial building located in Santiago, Chile. Different strategies of operation in a design day are assessed by computational simulation with EnergyPlus. A hybrid operation strategy is evaluated for the hottest summer week, and the results of the cooling loads are obtained. Finally, we founded that the implementation of a LHTES reduces by 7.8% the cooling energy consumption of the cooling system during the analyzed period. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
dc.fuente.origenWOS
dc.identifier.doi10.1016/j.ijrefrig.2019.01.028
dc.identifier.eissn1879-2081
dc.identifier.issn0140-7007
dc.identifier.urihttps://doi.org/10.1016/j.ijrefrig.2019.01.028
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/100958
dc.identifier.wosidWOS:000471866600015
dc.language.isoen
dc.pagina.final150
dc.pagina.inicio142
dc.revistaInternational journal of refrigeration-revue internationale du froid
dc.rightsacceso restringido
dc.subjectLatent heat thermal storage
dc.subjectIce tank
dc.subjectBuilding simulation
dc.subjectCooling loads
dc.subjectChiller plant
dc.subject.ods07 Affordable and Clean Energy
dc.subject.odspa07 Energía asequible y no contaminante
dc.titleFeasibility study of the application of a cooling energy storage system in a chiller plant of an office building located in Santiago, Chile
dc.typeartículo
dc.volumen102
sipa.indexWOS
sipa.trazabilidadWOS;2025-01-12
Files