Pulse Contour Analysis and Transesophageal Echocardiography: A Comparison of Measurements of Cardiac Output During Laparoscopic Colon Surgery
dc.contributor.author | Concha, Mario R. | |
dc.contributor.author | Mertz, Veronica F. | |
dc.contributor.author | Cortinez, Luis I. | |
dc.contributor.author | Gonzalez, Katya A. | |
dc.contributor.author | Butte, Jean M. | |
dc.date.accessioned | 2024-01-10T12:07:49Z | |
dc.date.available | 2024-01-10T12:07:49Z | |
dc.date.issued | 2009 | |
dc.description.abstract | BACKGROUND: Pulse wave analysis (PWA) allows cardiac output (CO) measurement after calibration by transpulmonary thermodilution. A PWA system that does not require previous calibration, the FloTrac/Vigileo (FTV), has been recently developed. We compared determinations of CO made with the FTV to simultaneous measurements using transesophageal echocardiography (TEE). | |
dc.description.abstract | METHOD: Ten ASA I-II patients scheduled for laparoscopic colorectal surgery were studied. A radial 20-gauge cannula was inserted and connected to a hemodynamic monitor and a FTV system for PWA and determination of CO (COPWA). TEE CO (COTEE) was determined as previously described. Measurements were made after intubation, 5 min after establishing the lithotomy position, 5 min after establishing pneumoperitoneum, every 30 min, or each time mean arterial blood pressure decreased below basal values. Statistical. analysis was made with the Bland and Altman method. | |
dc.description.abstract | RESULTS: Eighty-eight measurements were compared. The COTEE values ranged from 3.23 to 12 Lt/min (mean 6.21 +/- 1.85). Values for COPWA ranged from 2.9 to 8.5 Lt/min (mean 4.84 +/- 1.14). Bias was 1.17 and limits of agreement -2.02 and 4.37. The percentage error between all COTEE and COPWA measurements was 40% (27%-50%) mean (range). | |
dc.description.abstract | CONCLUSION: During laparoscopic colon surgery, clinically important differences were observed between CO determinations made with TEE and FTV. (Anesth Analg 2009;109:114-8) | |
dc.fechaingreso.objetodigital | 2024-05-15 | |
dc.format.extent | 5 páginas | |
dc.fuente.origen | WOS | |
dc.identifier.doi | 10.1213/ane.0b013e3181a491b8 | |
dc.identifier.issn | 0003-2999 | |
dc.identifier.pubmedid | MEDLINE:19535700 | |
dc.identifier.uri | https://doi.org/10.1213/ane.0b013e3181a491b8 | |
dc.identifier.uri | https://repositorio.uc.cl/handle/11534/76328 | |
dc.identifier.wosid | WOS:000267275100019 | |
dc.information.autoruc | Medicina;Butte JM;S/I;135616 | |
dc.information.autoruc | Medicina;Concha MR;S/I;61460 | |
dc.information.autoruc | Medicina;Cortínez LI;S/I;79356 | |
dc.information.autoruc | Medicina;Mertz VF;S/I;75458 | |
dc.issue.numero | 1 | |
dc.language.iso | en | |
dc.nota.acceso | contenido parcial | |
dc.pagina.final | 118 | |
dc.pagina.inicio | 114 | |
dc.publisher | LIPPINCOTT WILLIAMS & WILKINS | |
dc.revista | ANESTHESIA AND ANALGESIA | |
dc.rights | acceso restringido | |
dc.subject | ARTERIAL-PRESSURE WAVE | |
dc.subject | THERMODILUTION TECHNIQUE | |
dc.subject | FORM ANALYSIS | |
dc.subject | CATHETERIZATION | |
dc.subject | ANESTHESIA | |
dc.subject | SYSTEM | |
dc.subject.ods | 03 Good Health and Well-being | |
dc.subject.odspa | 03 Salud y bienestar | |
dc.title | Pulse Contour Analysis and Transesophageal Echocardiography: A Comparison of Measurements of Cardiac Output During Laparoscopic Colon Surgery | |
dc.type | artículo | |
dc.volumen | 109 | |
sipa.codpersvinculados | 135616 | |
sipa.codpersvinculados | 61460 | |
sipa.codpersvinculados | 79356 | |
sipa.codpersvinculados | 75458 | |
sipa.index | WOS | |
sipa.index | Scopus | |
sipa.trazabilidad | Carga SIPA;09-01-2024 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 2024-05-15. Pulse Contour Analysis and Transesophageal Echocardiography - A Comparison of Measurements of Cardiac Output During Laparoscopic Colon Surgery.pdf
- Size:
- 3.2 KB
- Format:
- Adobe Portable Document Format
- Description: