An off-resonance insensitive orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half scan time
dc.contributor.author | Mella, Hernan | |
dc.contributor.author | Wang, Hui | |
dc.contributor.author | Montalba, Cristian | |
dc.contributor.author | Uribe, Sergio | |
dc.date.accessioned | 2025-01-20T22:15:03Z | |
dc.date.available | 2025-01-20T22:15:03Z | |
dc.date.issued | 2021 | |
dc.description.abstract | Purpose: To develop an Off-Resonance Insensitive Orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half of the acquisition time. | |
dc.description.abstract | Methods: Phantom and mid-level left ventricle short-axis tagged images were acquired using CSPAMM, ORI-CSPAMM, O-CSPAMM, and the proposed ORI-O-CPAMM sequences to interrogate and compare its behavior under off-resonance effects produced by vegetable oil and subcutaneous and epicardial fat. The images were compared in terms of signal and the capacity to obtain complex difference and MICSR images. | |
dc.description.abstract | Results: Like ORI-CSPAMM, the proposed ORI-O-CSPAMM sequence removed almost completely the off-resonance artifacts produced during the tagging preparation. Tagging grids without DC components were obtained with ORI-O-CSPAMM using complex difference and MICSR from only two complementary images, which reduced the scan time to a half compared to CSPAMM and ORI-CSPAMM. The removal of off-resonance effects and the capacity to obtain MICSR images are advantages of ORI-O-CSPAMM over the O-CSPAMM sequence. | |
dc.description.abstract | Conclusion: We developed a novel and fast tagging sequence designed to remove off-resonance effects during the tagging preparation, and to obtain complex difference and MICSR grids in half of the scan time compared to CSPAMM and ORI-CSPAMM sequences, which could allow its application to clinical protocols. | |
dc.fuente.origen | WOS | |
dc.identifier.doi | 10.1002/mrm.28916 | |
dc.identifier.eissn | 1522-2594 | |
dc.identifier.issn | 0740-3194 | |
dc.identifier.uri | https://doi.org/10.1002/mrm.28916 | |
dc.identifier.uri | https://repositorio.uc.cl/handle/11534/94495 | |
dc.identifier.wosid | WOS:000672286200001 | |
dc.issue.numero | 6 | |
dc.language.iso | en | |
dc.pagina.final | 3033 | |
dc.pagina.inicio | 3022 | |
dc.revista | Magnetic resonance in medicine | |
dc.rights | acceso restringido | |
dc.subject | cardiac MRI | |
dc.subject | CSPAMM | |
dc.subject | MICSR | |
dc.subject | off-resonance insensitive | |
dc.subject | tagging | |
dc.subject.ods | 03 Good Health and Well-being | |
dc.subject.odspa | 03 Salud y bienestar | |
dc.title | An off-resonance insensitive orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half scan time | |
dc.type | artículo | |
dc.volumen | 86 | |
sipa.index | WOS | |
sipa.trazabilidad | WOS;2025-01-12 |