An off-resonance insensitive orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half scan time

dc.contributor.authorMella, Hernan
dc.contributor.authorWang, Hui
dc.contributor.authorMontalba, Cristian
dc.contributor.authorUribe, Sergio
dc.date.accessioned2025-01-20T22:15:03Z
dc.date.available2025-01-20T22:15:03Z
dc.date.issued2021
dc.description.abstractPurpose: To develop an Off-Resonance Insensitive Orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half of the acquisition time.
dc.description.abstractMethods: Phantom and mid-level left ventricle short-axis tagged images were acquired using CSPAMM, ORI-CSPAMM, O-CSPAMM, and the proposed ORI-O-CPAMM sequences to interrogate and compare its behavior under off-resonance effects produced by vegetable oil and subcutaneous and epicardial fat. The images were compared in terms of signal and the capacity to obtain complex difference and MICSR images.
dc.description.abstractResults: Like ORI-CSPAMM, the proposed ORI-O-CSPAMM sequence removed almost completely the off-resonance artifacts produced during the tagging preparation. Tagging grids without DC components were obtained with ORI-O-CSPAMM using complex difference and MICSR from only two complementary images, which reduced the scan time to a half compared to CSPAMM and ORI-CSPAMM. The removal of off-resonance effects and the capacity to obtain MICSR images are advantages of ORI-O-CSPAMM over the O-CSPAMM sequence.
dc.description.abstractConclusion: We developed a novel and fast tagging sequence designed to remove off-resonance effects during the tagging preparation, and to obtain complex difference and MICSR grids in half of the scan time compared to CSPAMM and ORI-CSPAMM sequences, which could allow its application to clinical protocols.
dc.fuente.origenWOS
dc.identifier.doi10.1002/mrm.28916
dc.identifier.eissn1522-2594
dc.identifier.issn0740-3194
dc.identifier.urihttps://doi.org/10.1002/mrm.28916
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/94495
dc.identifier.wosidWOS:000672286200001
dc.issue.numero6
dc.language.isoen
dc.pagina.final3033
dc.pagina.inicio3022
dc.revistaMagnetic resonance in medicine
dc.rightsacceso restringido
dc.subjectcardiac MRI
dc.subjectCSPAMM
dc.subjectMICSR
dc.subjectoff-resonance insensitive
dc.subjecttagging
dc.subject.ods03 Good Health and Well-being
dc.subject.odspa03 Salud y bienestar
dc.titleAn off-resonance insensitive orthogonal CSPAMM sequence (ORI-O-CSPAMM) for the acquisition of CSPAMM and MICSR grids in half scan time
dc.typeartículo
dc.volumen86
sipa.indexWOS
sipa.trazabilidadWOS;2025-01-12
Files