Reliability enhancement of the system with large amount of wind power integration

dc.contributor.authorRen, Hui
dc.contributor.authorChen, Y.
dc.contributor.authorTeng, Weijun
dc.contributor.authorWatts Casimis, David
dc.date.accessioned2022-05-13T19:15:16Z
dc.date.available2022-05-13T19:15:16Z
dc.date.issued2011
dc.description.abstractThe power output from wind farms is highly volatile, uncertain and hard to be predicted accurately. Then sometimes positive short-run correlation between variations of wind power output and load could bring more and larger disturbances in the system operation, bringing reliability and economic concerns. The integration of wind power generators in power systems poses some challenges, and besides installing extra reserve capacities, transmission reinforcement or other advanced controls may be required to avoid transmission overloads or voltage problem induced by wind power variation. Moreover, a well-developed transmission network may need less reserve capacity for a given reliability level, providing incentives for the research of this paper. In this paper, an optimization & sensitivity method is proposed to identify the vulnerable area of the transmission system with large amount of wind integration. IEEE-57 bus system is used as the test system. Test cases with various objective functions and allocation of reserve capacity are designed and therefore different upgrade schemes are obtained by the method. Monte Carlo simulation is used for the reliability & economic evaluation of the test system with a group of indices, including a new index - entropy. Test results and comparison show the effective of the method, and also the potential of entropy for assessing the robust of the transmission network.
dc.fuente.origenIEEE
dc.identifier.doi10.1109/PES.2011.6039533
dc.identifier.isbn978-1457710025
dc.identifier.issn1944-9925
dc.identifier.urihttps://doi.org/10.1109/PES.2011.6039533
dc.identifier.urihttps://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6039533
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/63872
dc.information.autorucEscuela de ingeniería ; Watts Casimis, David ; S/I ; 93141
dc.language.isoen
dc.nota.accesoContenido parcial
dc.publisherIEEE
dc.relation.ispartofPower and Energy Society General Meeting (2011 : Detroit, MI, Estados Unidos)
dc.rightsacceso restringido
dc.subjectWind power generation
dc.subjectReliability
dc.subjectGenerators
dc.subjectEntropy
dc.subjectLoad flow
dc.subjectWind farms
dc.subjectPower system reliability
dc.titleReliability enhancement of the system with large amount of wind power integrationes_ES