Off-resonance correction using an estimated linear time map

dc.contributor.authorAkel, JA
dc.contributor.authorRosenblitt, M
dc.contributor.authorIrarrazaval, P
dc.date.accessioned2024-01-10T12:07:05Z
dc.date.available2024-01-10T12:07:05Z
dc.date.issued2002
dc.description.abstractImages acquired in the presence of magnetic field deviations and reconstructed without taking into account the off-resonance, are distorted and corrupted with artifacts. Several post-processing algorithms have been developed for correcting the distortion when it is not possible to fix the field inhomogeneities. These off-resonance correction methods are, in general, slow and computing intensive. To make them faster they are usually adapted to a particular situation or approximated. One of these approximations is to assume that the field map is linear. Although this assumption makes the algorithm fast and robust it is not well suited for arbitrary field maps. On the other hand, there are k-space trajectories with an almost linear time map (time at which each k-space value is acquired), such as 2DFT and EPI. This paper presents an algorithm for off-resonance correction based on a linear time map approximation. This approximation allows a fast algorithm that takes advantage of the almost linearity of the time map and uses the whole field map to correct the images. The proposed correction algorithm reduces the off-resonance induced artifacts while being fast. The linear approximation of the time map needs to be done only once for each trajectory because it does not depend on the acquired image or field map data. The method can also be extended to a multi-plane approximation for sequences with more complex time maps. (C) 2002 Elsevier Science Inc. All rights reserved.
dc.fechaingreso.objetodigital2024-04-11
dc.format.extent10 páginas
dc.fuente.origenWOS
dc.identifier.doi10.1016/S0730-725X(02)00487-3
dc.identifier.issn0730-725X
dc.identifier.pubmedidMEDLINE:12034340
dc.identifier.urihttps://doi.org/10.1016/S0730-725X(02)00487-3
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/76243
dc.identifier.wosidWOS:000175869300007
dc.information.autorucIngeniería;Irarrázaval P;S/I;57376
dc.issue.numero2
dc.language.isoen
dc.nota.accesocontenido parcial
dc.pagina.final198
dc.pagina.inicio189
dc.publisherELSEVIER SCIENCE INC
dc.revistaMAGNETIC RESONANCE IMAGING
dc.rightsacceso restringido
dc.subjectfield-map
dc.subjecttime-map
dc.subjectoff-resonance
dc.subjectartifact
dc.subjectVARYING GRADIENTS
dc.subjectDISTORTION
dc.subject.ods03 Good Health and Well-being
dc.subject.odspa03 Salud y bienestar
dc.titleOff-resonance correction using an estimated linear time map
dc.typeartículo
dc.volumen20
sipa.codpersvinculados57376
sipa.indexWOS
sipa.indexScopus
sipa.trazabilidadCarga SIPA;09-01-2024
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Off-resonance correction using an estimated linear time map.pdf
Size:
2.87 KB
Format:
Adobe Portable Document Format
Description: