BeamCal Instrumentation IC: Design, implementation and test results

dc.contributor.authorAbusleme Hoffman, Ángel Christian
dc.contributor.authorDragone, A.
dc.contributor.authorHaller, G.
dc.contributor.authorWooley, B. A.
dc.date.accessioned2022-05-16T20:30:50Z
dc.date.available2022-05-16T20:30:50Z
dc.date.issued2011
dc.description.abstractThe BeamCal detector, one of the calorimeters in the forward region of the International Linear Collider detector, will serve three purposes: ensure hermeticity of the detector for small polar angles, reduce the backscattering from pairs into the detector center, and provide a low-latency signal for beam diagnostics. The BeamCal specifications in terms of noise suppression, signal charge, pulse rate and occupancy pose unique challenges in the front-end and readout electronics design. The Bean - BeamCal Instrumentation IC - is a 32-channel front-end and readout IC that will address the BeamCal instrumentation requirements. By employing switched-capacitor filters and a slow reset-release technique, the Bean will process the signal charge at the International Linear Collider pulse rate. Each channel will have a 10-bit successive approximation analog-to-digital converter and digital memory for readout purposes. The Bean will also feature a fast feedback adder, capable of providing an 8-bit, low-latency output for beam diagnostic purposes. This work presents the design and characterization of the Bean prototype, a 3-channel IC that proves the principle of operation described.
dc.fuente.origenIEEE
dc.identifier.doi10.1109/NSSMIC.2011.6154097
dc.identifier.eissn1558-1578
dc.identifier.issn0018-9499
dc.identifier.urihttps://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6154097
dc.identifier.urihttps://doi.org/10.1109/NSSMIC.2011.6154097
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/64003
dc.information.autorucEscuela de ingeniería ; Abusleme Hoffman, Ángel Christian ; S/I ; 2698
dc.issue.numero3
dc.language.isoen
dc.nota.accesoContenido parcial
dc.pagina.final596
dc.pagina.inicio589
dc.publisherIEEE
dc.relation.ispartofIEEE Transactions on Nuclear Science (2012)
dc.rightsacceso restringido
dc.subjectMoment methods
dc.subjectBiological system modeling
dc.titleBeamCal Instrumentation IC: Design, implementation and test resultses_ES
dc.typecomunicación de congreso
dc.volumen59
sipa.codpersvinculados2698
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
BeamCal Instrumentation IC - Design, implementation and test results.pdf
Size:
2.81 KB
Format:
Adobe Portable Document Format
Description: