BeamCal Instrumentation IC: Design, implementation and test results
dc.contributor.author | Abusleme Hoffman, Ángel Christian | |
dc.contributor.author | Dragone, A. | |
dc.contributor.author | Haller, G. | |
dc.contributor.author | Wooley, B. A. | |
dc.date.accessioned | 2022-05-16T20:30:50Z | |
dc.date.available | 2022-05-16T20:30:50Z | |
dc.date.issued | 2011 | |
dc.description.abstract | The BeamCal detector, one of the calorimeters in the forward region of the International Linear Collider detector, will serve three purposes: ensure hermeticity of the detector for small polar angles, reduce the backscattering from pairs into the detector center, and provide a low-latency signal for beam diagnostics. The BeamCal specifications in terms of noise suppression, signal charge, pulse rate and occupancy pose unique challenges in the front-end and readout electronics design. The Bean - BeamCal Instrumentation IC - is a 32-channel front-end and readout IC that will address the BeamCal instrumentation requirements. By employing switched-capacitor filters and a slow reset-release technique, the Bean will process the signal charge at the International Linear Collider pulse rate. Each channel will have a 10-bit successive approximation analog-to-digital converter and digital memory for readout purposes. The Bean will also feature a fast feedback adder, capable of providing an 8-bit, low-latency output for beam diagnostic purposes. This work presents the design and characterization of the Bean prototype, a 3-channel IC that proves the principle of operation described. | |
dc.fuente.origen | IEEE | |
dc.identifier.doi | 10.1109/NSSMIC.2011.6154097 | |
dc.identifier.eissn | 1558-1578 | |
dc.identifier.issn | 0018-9499 | |
dc.identifier.uri | https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6154097 | |
dc.identifier.uri | https://doi.org/10.1109/NSSMIC.2011.6154097 | |
dc.identifier.uri | https://repositorio.uc.cl/handle/11534/64003 | |
dc.information.autoruc | Escuela de ingeniería ; Abusleme Hoffman, Ángel Christian ; S/I ; 2698 | |
dc.issue.numero | 3 | |
dc.language.iso | en | |
dc.nota.acceso | Contenido parcial | |
dc.pagina.final | 596 | |
dc.pagina.inicio | 589 | |
dc.publisher | IEEE | |
dc.relation.ispartof | IEEE Transactions on Nuclear Science (2012) | |
dc.rights | acceso restringido | |
dc.subject | Moment methods | |
dc.subject | Biological system modeling | |
dc.title | BeamCal Instrumentation IC: Design, implementation and test results | es_ES |
dc.type | comunicación de congreso | |
dc.volumen | 59 | |
sipa.codpersvinculados | 2698 |