Final Two-Year Outcomes for the Sentry Bioconvertible Inferior Vena Cava Filter in Patients Requiring Temporary Protection from Pulmonary Embolism
dc.contributor.author | Dake, Michael D. | |
dc.contributor.author | Murphy, Timothy P. | |
dc.contributor.author | Kramer, Albrecht H. | |
dc.contributor.author | Darcy, Michael D. | |
dc.contributor.author | Sewall, Luke E. | |
dc.contributor.author | Curi, Michael A. | |
dc.contributor.author | Johnson, Matthew S. | |
dc.contributor.author | Arena, Frank | |
dc.contributor.author | Swischuk, James L. | |
dc.contributor.author | Ansel, Gary M. | |
dc.contributor.author | Silver, Mitchell J. | |
dc.contributor.author | Saddekni, Souheil | |
dc.contributor.author | Brower, Jayson S. | |
dc.contributor.author | Mendes, Robert | |
dc.contributor.author | Feezor, Robert | |
dc.contributor.author | Kalva, Sanjeeva | |
dc.contributor.author | Kies, Darren | |
dc.contributor.author | Bosiers, Marc | |
dc.contributor.author | Ziegler, Werner | |
dc.contributor.author | Farber, Mark | |
dc.contributor.author | Paolini, David | |
dc.contributor.author | Spillane, Robert | |
dc.contributor.author | Jones, Steven | |
dc.contributor.author | Peeters, Patrick | |
dc.contributor.author | SENTRY Trial Investigators | |
dc.date.accessioned | 2024-01-10T13:48:24Z | |
dc.date.available | 2024-01-10T13:48:24Z | |
dc.date.issued | 2020 | |
dc.description.abstract | Purpose: To report final 2-year outcomes with the Sentry bioconvertible inferior vena cava (IVC) filter in patients requiring temporary protection against pulmonary embolism (PE). | |
dc.description.abstract | Materials and Methods: In a prospective multicenter trial, the Sentry filter was implanted in 129 patients with documented deep vein thrombosis (DVT) and/or PE (67.5%) or who were at temporary risk of developing DVT/PE (32.6%). Patients were monitored and bioconversion status ascertained by radiography, computed tomography (CT), and CT venography through 2 years. | |
dc.description.abstract | Results: The composite primary 6-month endpoint of clinical success was achieved in 97.4% (111/114) of patients. The rate of new symptomatic PE was 0% (n = 126) through 1 year and 2.4% (n = 85) through the second year of follow-up, with 2 new nonfatal cases at 581 and 624 days that were adjudicated as not related to the procedure or device. Two patients (1.6%) developed symptomatic caval thrombosis during the first month and underwent successful interventions without recurrence. No other filter-related symptomatic complications occurred through 2 years. There was no filter tilting, migration, embolization, fracture, or caval perforation and no filter-related deaths through 2 years. Filter bioconversion was successful for 95.7% (110/115) of patients at 6 months, 96.4% (106/110) of patients at 12 months, and 96.5% (82/85) of patients at 24 months. Through 24 months of follow-up, there was no evidence of late-stage IVC obstruction or thrombosis after filter bioconversion or of thrombogenicity associated with retracted filter arms. | |
dc.description.abstract | Conclusions: The Sentry IVC filter provided safe and effective protection against PE, with a high rate of intended bioconversion and a low rate of device-related complications, through 2 years of follow-up. | |
dc.description.funder | BTG Vascular (Bothell, Washington) | |
dc.fechaingreso.objetodigital | 01-04-2024 | |
dc.format.extent | 10 páginas | |
dc.fuente.origen | WOS | |
dc.identifier.doi | 10.1016/j.jvir.2019.08.036 | |
dc.identifier.eissn | 1535-7732 | |
dc.identifier.issn | 1051-0443 | |
dc.identifier.pubmedid | MEDLINE:31711748 | |
dc.identifier.uri | https://doi.org/10.1016/j.jvir.2019.08.036 | |
dc.identifier.uri | https://repositorio.uc.cl/handle/11534/79362 | |
dc.identifier.wosid | WOS:000514221100005 | |
dc.information.autoruc | Medicina;Kramer Schumacher Albrecht Hel;S/I;98256 | |
dc.issue.numero | 2 | |
dc.language.iso | en | |
dc.nota.acceso | contenido completo | |
dc.pagina.final | 230 | |
dc.pagina.inicio | 221 | |
dc.publisher | ELSEVIER SCIENCE INC | |
dc.revista | JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY | |
dc.rights | acceso abierto | |
dc.subject | DENALI TRIAL | |
dc.subject | COMPLICATIONS | |
dc.subject | MULTICENTER | |
dc.subject | PLACEMENT | |
dc.subject | TRAUMA | |
dc.subject.ods | 03 Good Health and Well-being | |
dc.subject.odspa | 03 Salud y bienestar | |
dc.title | Final Two-Year Outcomes for the Sentry Bioconvertible Inferior Vena Cava Filter in Patients Requiring Temporary Protection from Pulmonary Embolism | |
dc.type | artículo | |
dc.volumen | 31 | |
sipa.codpersvinculados | 98256 | |
sipa.index | WOS | |
sipa.trazabilidad | Carga SIPA;09-01-2024 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 2024-04-01. Final Two-Year Outcomes for the Sentry Bioconvertible Inferior Vena Cava Filter in Patients Requiring Temporary Protection from Pulmonary Embolism.pdf
- Size:
- 1.65 MB
- Format:
- Adobe Portable Document Format
- Description: