Absolute reliability and concurrent validity of a novel electromechanical pulley dynamometer for measuring shoulder rotation isometric strength in asymptomatic subjects. Study conducted at Pontificia Universidad Catolica, Santiago, Chile

dc.contributor.authorChamorro, Claudio
dc.contributor.authorDe la Fuente, Carlos
dc.contributor.authorRubio, Jose
dc.contributor.authorCampos, Christian
dc.contributor.authorJavier Chirosa, Luis
dc.date.accessioned2025-01-23T21:11:59Z
dc.date.available2025-01-23T21:11:59Z
dc.date.issued2019
dc.description.abstractObjective: To estimate the test-retest reliability of measurements in shoulder internal and external rotators' isometric peak torque using a new dynamometer, and to compare it with isokinetic dynamometer.
dc.description.abstractMethods: The validity study was conducted in September-October 2016 at Pontificia Universidad Catolica de Chile and the Clinica Las Condes, Santiago, Chile. It comprised of asymptomatic university students who were randomly tested twice within a two-week period while in a supine position at 90 of shoulder abduction, using the novel functional electromechanical pulley dynamometer. Concurrent validity was assessed through comparing the values with the gold standard isokinetic dynamometer in the same position. SPSS 17 was used for data analysis.
dc.description.abstractResults: Of the 24 subjects, 5(21%) were males and 19(79%) were females. The overall mean age was 23.1 +/- 2.2 years, body mass index 23.6 +/- 2.13 kg/m(2) and Shoulder Pain and Disability Index score was 3.9 +/- 6.4. There was no statistically non-significant difference in terms of test-retest trials and between the devices (p>0.05). Absolute reliability was 243% for internal rotation and 27.9% for external rotation. Both dynamometer systems were very highly correlated for internal rotators peak torque (0.93) and highly correlated for external rotators peak torque (0.84).
dc.description.abstractConclusions: Compared to the gold standard, the new device was found to be a valid instrument in measuring maximal voluntary isometric peak torque in internal and external rotation.
dc.fuente.origenWOS
dc.identifier.issn0030-9982
dc.identifier.urihttps://repositorio.uc.cl/handle/11534/100935
dc.identifier.wosidWOS:000474769200015
dc.issue.numero7
dc.language.isoen
dc.pagina.final1005
dc.pagina.inicio1000
dc.revistaJournal of the pakistan medical association
dc.rightsacceso restringido
dc.subjectMuscle strength dynamometer
dc.subjectReliability of results
dc.subjectRotator cuff
dc.titleAbsolute reliability and concurrent validity of a novel electromechanical pulley dynamometer for measuring shoulder rotation isometric strength in asymptomatic subjects. Study conducted at Pontificia Universidad Catolica, Santiago, Chile
dc.typeartículo
dc.volumen69
sipa.indexWOS
sipa.trazabilidadWOS;2025-01-12